1392 XXXI International Mineral Processing Congress 2024 Proceedings/Washington, DC/Sep 29–Oct 3
to trigger the hammer’s release onto the fragment in the
cup. The sample cup sits in a dedicated grooved inset on
the base-plate’s top surface and comprises a handle allow-
ing a user to easily remove the sample cup from the frame
during testing.
SAMPLE INVENTORY
Seven lump rock samples were selected for the small frag-
ment HIT test trial with the total mass ranging from 1.95
to 5.93kg. Table 1 and Figure 2 show the samples and
quantity as received.
Table 1. Summary of Samples Received by BML
Figure 2. Images of seven samples supplied for proof-of-concept tests